To give you the best possible experience, this site uses cookies. Using your site means your agree to our use of cookies. We have published a new cookies policy, which you should need to find out more about the cookies we use. View Cookies Policy.
Carte BMS 14S 50.4V 30A
  • new
Imprimante 3D Bambu Lab A1 COMBO
  • new
      Oxymètre de pulsations
      Oxymètre de pulsations

      Oxymètre de pulsations

      80,000 TND
      TTC
      Rupture de stock

      Quantity :
      Donnez votre avis

      EU3234363840424446USXX5XSSMLXLXXLXXLArm Length6161,56262,56363,56464,5Bust Circumference8084889296101106111Waist Girth6165697377828792Hip Circumference87919599103108113118

      • Paiement:Paiement: Tous les types de paiement disponibles
      • Livraison:Livraison: Option de mode de livraison diversifiée
      • Politique retoursPolitique retours Echange ou remboursement possible sous conditions

      Measures Blood Oxygen Level (SpO2) and Heart Rate (pulse)

      This fingertip pulse oximeter offers an affordable, reliable and precise way to check your pulse rate and blood oxygen saturation levels – whenever, and wherever. The Pulse Oximeter features a one-button operation to determine your blood oxygen saturation levels ( SpO2) as well as your heart rate (pulse).

      Display Format: LCD Display

      SpO2 Measuring Range: 0% ~ 100%

      Pulse Rate Measuring Range: 30 bpm ~ 250 bpm

      Pulse Wave Display: columniation display and the waveform display.

      Power Requirement: 2x 1.5 V AAA Alkaline battery ( or using the rechargeable battery instead), adaptable range: 2.6 V – 3.6V

      Power Consumption: Smaller than 30 mA

      Resolution: 1% for SpO2 and 1 bpm for Pulse Rate.

      Measurement Accuracy: ±2% in a stage of 70%-100% SpO2, and meaningless when the stage being smaller than 70% ±2 bpm during the pulse rate range of 30-99 bpm and ±2% during the pulse rate range of 100~250 bpm. Clinical Trial: SpO2 regression plot & Bland-Altman plot, Refer to Figure 2 & Figure 3.

      Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when the pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm during the pulse rate range of 30~99 bpm and ±2% during the pulse rate range of 100~250 bpm.

      Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and darkroom is less than 1%.

      Equipped with a function switch: The product will enter the standby mode when no signal is in the product within 5 seconds.

      Optical Sensor:

      Red light (wavelength is 660 nm, 6.65 mW)

      Infrared (wavelength is 880 nm, 6.75 mW)

      1000-00698

      Références spécifiques

      Oxymètre de pulsations

      Oxymètre de pulsations

      80,000 TND
      TTC