      Measures Blood Oxygen Level (SpO2) and Heart Rate (pulse)

      This fingertip pulse oximeter offers an affordable, reliable and precise way to check your pulse rate and blood oxygen saturation levels – whenever, and wherever. The Pulse Oximeter features a one-button operation to determine your blood oxygen saturation levels ( SpO2) as well as your heart rate (pulse).

      Display Format: LCD Display

      SpO2 Measuring Range: 0% ~ 100%

      Pulse Rate Measuring Range: 30 bpm ~ 250 bpm

      Pulse Wave Display: columniation display and the waveform display.

      Power Requirement: 2x 1.5 V AAA Alkaline battery ( or using the rechargeable battery instead), adaptable range: 2.6 V – 3.6V

      Power Consumption: Smaller than 30 mA

      Resolution: 1% for SpO2 and 1 bpm for Pulse Rate.

      Measurement Accuracy: ±2% in a stage of 70%-100% SpO2, and meaningless when the stage being smaller than 70% ±2 bpm during the pulse rate range of 30-99 bpm and ±2% during the pulse rate range of 100~250 bpm. Clinical Trial: SpO2 regression plot & Bland-Altman plot, Refer to Figure 2 & Figure 3.

      Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when the pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm during the pulse rate range of 30~99 bpm and ±2% during the pulse rate range of 100~250 bpm.

      Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and darkroom is less than 1%.

      Equipped with a function switch: The product will enter the standby mode when no signal is in the product within 5 seconds.

      Optical Sensor:

      Red light (wavelength is 660 nm, 6.65 mW)

      Infrared (wavelength is 880 nm, 6.75 mW)

      1000-00698